IJAR.2019.226

Type of Article:  Original Research

Volume 7; Issue 3.1 (July 2019)

Page No.: 6786-6789

DOI: https://dx.doi.org/10.16965/ijar.2019.226

MORPHOLOGICAL VARIATIONS OF UMBILICAL CORD IN HUMAN PLACENTA

Siva Sree Ranga. M.K *1, Vasantha Mallika. M.C 2.

*1 Associate Professor, Department of  Anatomy, Sree Mookambika Institute of Medical Sciences, Kulasekharam, South India.

2 Professor, Department of Community Medicine, Sree Mookambika Institute of Medical Sciences, Kulasekharam, South India.

Corresponding Author: Dr. M K Siva Sree Ranga, Siva Sree Sadanam, Vellarada, Thiruvananthapuram – 695 505, Kerala, India. Phone: +91-9447696069. E-Mail: dr.sivasreeranga@gmail.com

ABSTRACT:

Introduction: The umbilical cord or Funis  forms the connecting link between the fetus and the placenta. Through umbilical cord the fetal blood flows to and from the placenta providing nutrition, gas exchange, waste removal, endocrine function and immune support to the developing fetus. The umbilical cord extends from the fetal umbilicus to the fetal surface of the placenta. Being organs of vital importance for continuation of pregnancy, the placenta and umbilical cord have evolved great interest among the Anatomists, Embryologists, Pathologists and Obstetricians.

Materials and Methods: A cross sectional study was conducted on 695 umbilical cords attached to placentae from the Department of Obstetrics and Gynaecology, collected soon after delivery. The morphology of the umbilical cords attached to placenta were studied. Fresh specimens of umbilical cord were examined for attachment to the placenta, cord length, diameter, number of vessels, diameter of vessels, coiling and knotted appearance. Neonatal details within 24 hours after delivery were recorded.

Results:  Average cord length was 46.04cm (SD 11.8cm) with the shortest cord being 5.8cm and the longest 78.50cm. Majority of the umbilical cords (71.94%) had eccentric attachment to the placentae; (139) 20% had central and 53(7.63%) had marginal and 3(0.43%) had velamentous attachments .  Occurrence of furcate insertion of umbilical cord vessels into the placenta was 28% and non-furcate insertion was 501(72%). Morphological variations of umbilical cord showed statistically significant association with maternal Diabetes mellitus, Preeclampsia, Antepartum haemorrhage, twin pregnancy and foetal Intra Uterine Growth Retardation.

Conclusion: The study observed that, the morphological variations of umbilical cord  show significant effects on maternal and foetal conditions.  These quantitative findings may provide baseline information for further investigations.

Key words: Umbilical cord, Placenta, Morphology, Variations.

REFERENCES

  1. Asra A, Suseelamma D, Sarita S, Ramani T V, Nagajyothi D. Study of morphological variations of 50 placentae with umbilical cords and its developmental relevance. Int J Anat Res. 2015;3(3):1259-66.
  2. Tangirala S, kumari D. Placental morphology in hypertensive disorders and its correlation to neonatal outcome. IAIM 2015;2:35-8.
  3. Sornes,T.Umbilical cord knots. Acta Obstet Gynaecol Scand Mar;79(3): 157-159
  4. Calvano,C.J., Hoar,R.M., Mankes,R.F., Lefevre,R., Reddy,P.P., Moran,M.E.& Mandell, J. Experimental study of umbilical cord length as a marker offetal alcohol syndrome.Teratology, 2000;61(3):184-188.
  5. Pennati G. Biochemical properties of the human umbilical cord, Biorheology. 2001;38(5-6):355-366.
  6. Peter Kwabena Appiah. Relationship between the morphology of placenta, Umbilical cord and Perinatal Outcome,2009.
  7. Gupta, S., Faradi, M. M. A and Krishnan, J. Umbilical cord Index. Journal of Gynecology, India, 2006;56(4):315-319.
  8. Peter Kwabena Appiah. Relationship between the morphology of placenta, Umbilical cord and Perinatal Outcome,2009.
  9. Udaina A, Bhagwat SS, Mehta CD. Relation between placental surface area, infarction and foetal distress in pregnancy induced hypertension with its clinical relevance. J Anat Soc India 2004;53:27-30.
  10. Majumdar S, Dasgupta H. A study of placenta in normal and hypertensive pregnancies. J Anat Soc India 2005;54:1-9.
  11. Yousuf M S, Tarannum Y, Naval K P. Variations in the placental attachment of umbilical cord and its clinical significance. Journal of Medical and Dental Science. 2016;1-7.
  12. Vijayalakshmi B, Kittali S. Morphological changes of placenta in cases of pre-eclampsia and perinatal outcome. Int J Sci Stud 2015;3:137-42.
  13. Rodriguez MA four-vessel umbilical cord without congenital abnormalities. South Med J 1984 Apr;77(4):539.
  14. Machin, G. A., Ackerman, J. and Gilbert-Barness, E. Abnormal umbilical cord coiling is associated with adverse perinatal outcomes. Paediatric and Developmental Pathology, 2000;3:465-471.
  15. Cunningham FG, Gant NF, Leveno KJ, Gilstron LC, Hauth JC, Wenstrom KD. Abnormalities of the umbilical cord. Williams Obstetrics. 21st ed. New York: McGraw-Hill Medical Publishing Division, 2001;831-835.

Cite this article: Siva Sree Ranga. M.K, Vasantha Mallika. M.C. MORPHOLOGICAL VARIATIONS OF UMBILICAL CORD IN HUMAN PLACENTA. Int J Anat Res 2019;7(3.1):6786-6789. DOI: 10.16965/ijar.2019.226